1Parani-MSP1000For Wireless Multi-Serial Communications,based on Bluetooth TechnologyUser GuideVersion 1.2.7
10Common power supply options:Power via a standard AC-plug DC-adapterHardware interfaceLAN 10/100 x 2Inclusive hub functionEthernet/RS232C COM support
112. Getting Started2.1. External ViewFigure 2-1 External view of the Parani-MSP10002.2. LED IndicatorsThe Parani-MSP1000 has a number of LED indicato
122.3. Connecting the HardwareThis section describes how to connect the Parani-MSP1000 to your equipment for initialtesting/installation.- Connect the
13Figure 2-3 Connecting a network cable to the Parani-MSP10002.4. ConfigurationsThe Parani-MSP1000 provides several techniques to configure your unit
142.4.1. Configuration using the RS232 serial connection1) Connect one end of the console cable to the console port on the Parani-MSP1000.Figure 2-4 C
15[root@MSP1000 /]# editconf-------------------------------------------------------------------------------Welcome to MSP1000 configuration pageCurren
162.4.2. Configurations using Ethernet connectionThe IP address of the Parani-MSP1000 must be known before users can access the box using theRemote co
17Figure 2-6 The Parani-MSP1000 web management screenFigure 2-6 shows the configuration homepage of the Parani-MSP1000 Web management interface. Amenu
18Please refer to the following:1) Attach the power adapter to the Parani-MSP1000. Do not attach the Ethernet cable on theMSP1000 or the PC.2) Search
193. Network Configuration3.1. IP Configuration3.1.1. Ethernet 0 (eth0) configurationThe Parani-MSP1000 requires a valid IP address to operate within
2User Guide for the Parani-MSP1000Firmware version 1.2.XLast revised on Dec. 26, 2011Printed in KoreaCopyrightCopyright 2007~2012, Sena Technologies,
203.1.1.1. When using a Static IP AddressWhen using a Static IP address, the user must manually specify all the configuration parametersassociated wit
21usually easier to remember. The DNS server is the host that can translate such text-based domainnames into the numeric IP addresses for a TCP/IP con
223.1.2. Ethernet 1 (eth1) configurationThe Parani-MSP1000 has two Ethernet ports. The users may configure the secondary Ethernet (eth1)to “Bridged wi
23After enabling the Dynamic DNS service in the Dynamic DNS Configuration menu, the user must enterthe registered Domain Name, User Name, and Password
24Figure 3-3 SMTP Configuration3.4. IP filtering ConfigurationThe Parani-MSP1000 prevents unauthorized access using an IP address based filtering meth
2523(Telnet), 22(SSH), 80(HTTP), 443(HTTPS) or each Serial Port Profile session. Chain ruleSet the basic rule for the host to access the Parani-MSP10
26To use the TCP “keep-alive” feature with the Parani-MSP1000, the users should configure threeparameters as follows: TCP keep-alive time:This repres
274. Bluetooth Configuration4.1. General propertiesThis menu describes configuration for the Bluetooth parameters of the Parani-MSP1000. Bluetooth fr
280x05: Peripheral (mouse, joystick, keyboards, …)0x06: Imaging (printing, scanner, camera, display, …)Minor Device Class:The meaning of this byte dep
294.2.1 AP modeBluetooth devices that supports PAN, DUN and LAP have the ability to access the LAN through theParani-MSP1000.4.2.2 Repeater modeParani
3Revision HistoryRevision Date Name DescriptionV1.0.0 2007-09-11 Hanjun Yeom Final v1.0.0 releaseV1.1.1 2008-01-11 Hanjun Yeom Revised for v1.1.0 rele
304.2.3. Station modeThe Station transfers data from Repeater to outside. A Bluetooth module of Station can be connectedfrom seven Repeaters. But Repe
31172.16.0.50 ~ 172.16.0.99 Reserved for PAN connections172.16.0.100 ~ 172.16.0.200 Reserved for LAP & DUN connections 192.168.0.1 ~ 192.168.0.25
32The Port forwarding configuration has four parameters as follows: Local portThe source TCP or UDP port number Remote IPThe destination IP address
334.5. ConnectionsThe Bluetooth connections currently connected to the Parani-MSP1000 are displayed. Definitions anddescriptions of each parameter are
345. Serial Port Profile (SPP) ConfigurationThe Bluetooth devices that support Serial Port Profile are able to create connections with the Parani-MSP1
35 Scan intervalThe Parani-MSP1000 scans neighborhood Bluetooth devices with this interval (in seconds). Thisvalue means the time required for the Pa
36Figure 5-2 Port configuration5.5.1. Port pairing mode (Custom mode only)If the mode is “Acceptor”, the Parani-MSP1000 waits for incoming connection
37Figure 5-4 Service category - Network5.5.4. Service category – Serial hubIn Serial hub mode, Parani-MSP1000 relays data communications between Bluet
38 TimeoutThe Parani-MSP1000 waits until the received data size is the configured fixed size or the timer isexpired. If the timeout is zero, it means
39remote host like the client mode. In vertex mode, data from a host are sent to all of connectedBluetooth devices.Figure 5-7 Server modeFigure 5-8 Cl
4Contents1. Introduction 81.1. Overview ...
40Figure 5-10 Vertex mode Service protocolWhen the network service mode is server or client, the available protocols are RawTCP, SSL,Telnet and SSH.
41 Periodic connectionWhen the network service mode is client, the Parani-MSP1000 attempts to create an outgoingconnection with this interval. If the
42Figure 5-11 Port Logging mode5.5.8. Serial hubThe serial hub mode is supported only when the Pairing mode is “Custom”. This field shows BDaddress of
435.5.9. Miscellaneous 7-bit data emulationThis option is useful in using with the Parani-SD Series or the Parani-ESD Series. The Parani-SD/ESD Serie
445.7. ConnectionsThe SPP connections currently connected to the Parani-MSP1000 are displayed. Definitions anddescriptions of each parameter are descr
45Current time : 07/28/0107 16:03:36 Serial No. : msp1000-test-2F/W Rev. : v0.0.1_0827_1 MAC Addr.(eth0) : 00:01:95:AF:BE:11IP Mode (eth0) : Static IP
466. CF card ConfigurationThe Parani-MSP1000 has a CF card slot for increased expandability. It supports two types of PCcards:- ATA/IDE fixed disk car
476.2 Serial modem card configurationThe user can access to the Parani-MSP1000 via serial modem. The user can configure User name,Password, Authentica
487. System administration7.1. Host nameThe Parani-MSP1000 has its own name for administrative purposes.Figure 7-1 Host name configuration7.2. User ma
497.2.1. Adding a new userIn order to add a new user:1. Select “Add” button.2. Enter the username (user id)3. Choose the user group between admin and
54.5. Connections ...335. Se
50Figure 7-3 Security configuration7.3.1. Changing certificateThe Parani-MSP1000 supports .PEM format for certificate.In order to change the certifica
51not be established.In order to upload a new certificate of trusted CA:1. Select Certificates of Trusted CA menu2. Select the certificate file of CA3
52will allow the date and time information to be kept maintained by the internal battery backup.The user may also need to set the timezone and the tim
534. Click the [Export] button.Figure 7-5 Configuration exportTo import the exported configurations:1. Select the location to import from.2. Select th
547.6.1 Manual firmware upgradeTo upgrade firmware via the web:1. Select the latest firmware binary by clicking browse button.2. Select and upload the
55-------------------------------------------------------------------------------System administrator-------------------------------------------------
56 Automatic firmware and configuration upgrade at boot timeIt determines whether the Parani-MSP1000 upgrade at boot time or not. ProtocolIt determi
57Hash file example is below:1,msp1000.img,v1.0.02,conf.enc,E,v1.0.03,userfile.tar.gz,FXZ,/mnt/ram4,mkdir /mnt/ram/testdirFigure 7- 8 Automatic firmwa
588. System status & log8.1. System statusThe Parani-MSP1000 displays the system status. This screen is used for management purposes.System status
59IP address and the facility to be used.To receive log messages from the Parani-MSP1000, the SYSLOG server must be configured as“remote reception all
67.6.1 Manual firmware upgrade ...547.6.2. Automatic firmw
609. System statistics9.1. Network interfacesNetwork interfaces statistics displays basic network interfaces usage of the Parani-MSP1000, lo, eth0and
61discarded because the IP address in their IP header’s destination field was not a valid address tobe received at this entity. This count includes in
62Specifies the number of datagrams that need to be fragmented but couldn’t be because the IPheader specifies no fragmentation. For example, if the da
63number of routers it has passed through exceeds its time-to-live value.InParmProbs, OutParmProbs :Specifies the number of parameter-problem messages
64Figure 9-3 ICMP statistics9.4. TCPThe TCP Statistics screen provides statistical information about packets/connections using a TCPprotocol. Definiti
65PassiveOpens :Specifies the number of passive opens. In a passive open, the server is listening for a connectionrequest from a client.AttemptFails :
66InDatagrams :Specifies the number of datagrams received.NoPorts :Specifies the number of received datagrams that were discarded because the specifie
6710. CLI guide10.1. IntroductionThe Parani-MSP1000 Root user can access the Linux console command line interface (CLI) of theParani-MSP1000 by via th
68Telnet/SSH console:1) telnet Parani-MSP1000_ip_address or2) ssh root@ Parani-MSP1000_ip_address10.4. Running user-defined scriptsShell script /usr2/
6911. Approval Information11.1. FCC11.1.1. FCC Compliance StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the fol
7A.1. Console pin-outs...71A.2. Eth
7012. RF Information12.1. Radio Frequency Range2.402~2.480GHz12.2. Number of Frequency Channel79 channels12.3. Transmission MethodFHSS(Frequency Hoppi
71Appendix A. ConnectionsA.1. Console pin-outsThe pin assignment of the Parani-MSP1000 DB9 connector is summarized in Table A-1. Each pin hasa functio
72Figure A-3 Ethernet connection using straight through Ethernet cable
73Appendix B. Well-known port numbersPort numbers are divided into three ranges: Well Known Ports, Registered Ports, and Dynamic and/orPrivate Ports.
74Appendix C. Using PythonThe Parani-MSP1000 supports python language for user customization.C.1. Running PythonThere are two different ways to start
75Warning: Permanently added '192.168.7.8' (RSA) to the list of known [email protected]'s password:array.so 100% 101KB 101.4KB/s 0
76(23, "information"))for bitpos, classname in service_classes:if device_class & (1 << (bitpos-1)) and classname == "objecttr
77sleep(scan_interval)Step 2. Upload the Python code[root@MSP1000 usr2]# scp 192.168.7.8:/home/btsender.py ./[email protected]'s password:btsender
78Appendix D. Control CommandsThe Parani-MSP1000 is controllable by Control commands through 2525 TCP port. Every commandresponds with +OK if successf
79Synopsis STATDescriptionDisplays current Bluetooth device status.Idx|bdaddr|tx-byte|rx-byte|tx-error|rx-errorExampleSTAT0|00:01:95:00:00:D2|131570|2
81. Introduction1.1. OverviewThe Parani-MSP1000 is a Bluetooth Access Point used to enable Bluetooth devices to be connectedto a 10/100Mbps Ethernet n
80Synopsis LOG [line]Description To see system log. If line number specified, only latest [line] rows will be displayed.ExampleLOG 1Apr 11 01:42:13 MS
81Appendix E. WarrantyE.1. GENERAL WARRANTY POLICYSena Technologies, Inc. (hereinafter referred to as SENA) warrants that the Product shall conform to
82- Water spills,- Replacement of parts due to normal wear and tear,- Hardware has been altered in any way,- Product that has been exposed to repair a
9- Security/Access control system- General data acquisition application- Truck/Bus monitoring system- Car diagnosticsPlease note that this manual assu
Comments to this Manuals