Sena Parani-SD1000U User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
4. Multiple Connection Mode
4.1. Overview
Parani-SD1000U supports multiple connections up to 4 slave units. There are two types of multiple
connection modes: Multi-Drop Mode and Node Switching Mode.
M
S1 S4
S3S2
Figure 4-1 Multi-Drop Mode
In Multi-Drop Mode a master unit can connect to maximum 4 slave units at the same time and they
transfer data bi-directionally as in Figure 4-1.
M
S1 S4
S3S2
Figure 4-2 Node Switching Mode
In Node Switching Mode, the master unit maintains multiple connections with maximum 4 slave units
but only one connection with one slave unit is active and data is transferred as shown in Figure 4-2.
After connected to slave, master acts command mode. Active slave is selected by AT commands.
On communication after connecting
ATO1 Communicating with #1 Slave
+++
OK
ATO000195000003 Communicating with slave of BD 000195000003
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 48 49