par1 = PPPoE username,
par2 = PPPoE password
Figure 2-15 Help screen with ip’group specified
2.4.4 factorydefault’Command
With factorydefault’command, users can load factory default parameter values in console. Command
usage of factorydefaultis as follows:
factorydefault [option] + <CR>
where,
- if option is omitted, all parameters are set with factory default values.
- if option='-ip', all parameters except IP settings are set with factory default values.
Loaded values are not saved until save’command invoked. Afterfactorydefaultcommand,saveand
rebootcommands are required for changes to take effect.
> factorydefault (or factorydefault –ip)
OK
> save
OK
> reboot
Figure 2-16 Factory default reset screen
2.4.5 save’Command
With save’command, current parameter changes are saved to non-volatile memory. Command usage
of save’command is as follows:
save + <CR>
Saved changes will be applied if the LS100W is rebooted by reboot’command or manual rebooting.
2.4.6 exit’Command
With exitcommand, current serial or remote console session will be closed. However, changed
parameters are not applied until the LS100W is manually rebooted. Command usage of exit
command is as follows:
exit + <CR>